DataStage: ParamName does not reference a known parameter of the job

Today I got an error that reads like this:

 

JobControl (@<JOB_NAME>): Controller problem: Error

calling DSSetParam($<PARAMETER_NAME>), code=-3

[ParamName does not reference a known parameter of the job]

 

After a quick debug/issue tracking session on Director I found out that

one of the jobs in my master sequence was missing all of our standard

parameters with database user, schema and password, since we define

them at the project level all I had to do is click on All to

default and the problem was promptly fixed.