flickr-free-ic3d pan white

11-16mm Contact 2

Contact alignment issue

Cause's the FEE error in between the focal length of 12 - 13mm.

The third contact down in the pic was shorting on the fine PCB trace between the actual contacts.

Careful 'adjustment'... of the wiper mount cured the problem.

Happy days!!!

165 views
0 faves
0 comments
Taken on October 13, 2011