07/5/07 : Substation Inspection

07/5/07 : Substation Inspection

SF6 compartment of the RMU

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

07/5/07 : Substation Inspection

07/5/07 : Substation Inspection

F&G 11kV RMU at Business Centre KHTP

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

07/5/07 : Substation Inspection

07/5/07 : Substation Inspection

F&G 11kV RMU at Business Centre - Neon Indicator Light

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

07/5/07 : Substation Inspection

07/5/07 : Substation Inspection

Siemens 33kV SF6 CB at Air Product

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

07/5/07 : Substation Inspection

07/5/07 : Substation Inspection

33kV CB SF6 gauge

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

07/5/07 : Substation Inspection

07/5/07 : Substation Inspection

33kV SF6 circuit breakers at Air Products

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

04/5/07 : 132/33kV Tx 2

04/5/07 : 132/33kV Tx 2

132kV outdoor type switchgear

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

04/5/07 : 132/33kV Tx 2

04/5/07 : 132/33kV Tx 2

OLTC oil gauge removed

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

04/5/07 : 132/33kV Tx 2

04/5/07 : 132/33kV Tx 2

defected OLTC oil gauge

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

04/5/07 : 132/33kV Tx 2

04/5/07 : 132/33kV Tx 2

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

26/04/07 : 33kV cable fault

26/04/07 : 33kV cable fault

Cable fault locator van

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

26/04/07 : 33kV cable fault

26/04/07 : 33kV cable fault

Fault location at Intel KM5 new plant project

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

26/04/07 : 33kV cable fault

26/04/07 : 33kV cable fault

Identifying the location of the faulted cable

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

26/04/07 : 33kV cable fault

26/04/07 : 33kV cable fault

TDR analysis for fault locating

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

26/04/07 : 33kV cable fault

26/04/07 : 33kV cable fault

Air bubbles at the faulted cable location

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

25/4/07 : Substation Inspection

25/4/07 : Substation Inspection

Solkor RF relay operated

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

25/4/07 : Substation Inspection

25/4/07 : Substation Inspection

11kV Earth Switch in "close" condition

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

25/4/07 : Substation Inspection

25/4/07 : Substation Inspection

33kV Control panel at Fujimi

Anyone can see this photo All rights reserved

Uploaded on May 17, 2007

0 comments

← prev 1 2 3
(52 items)